Error Code | Component | Description | Checks to Perform | Solution |
E01 | Power Supply | Insufficient power supply or faulty control board | Check mains voltage and electronic control board | Replace the power module |
E02, E04 | Heating Element | Heating element malfunction | Inspect electronic board, heating relay, and resistance | Replace zeolite resistance and/or power module |
E03 | Heating Relay | Faulty drying relay operation | Check electronic board, drying relay, and resistance | Replace the power module |
E05 | Water Diverter | Continuous water connection issue | Check triac controlling water switch motor | Replace the power module |
E06 | Hall Sensor | Hall sensor error (short circuit or disconnection) | Inspect Hall sensor cables/connectors and measure voltage | Replace faulty Hall sensor |
E07 | Drying System | Drying system not working | Check fan, fan module, and zeolite drying coil | Replace defective parts |
E08, E09 | Heating Element | Heating issues due to low water level, low voltage, or heating circuit fault | Check exchanger valve for leaks, test heating resistance, inspect power relay and connections | Fix leaks or replace faulty heating components |
E10 | Heating System | Zeolite heating failure | Inspect heating circuit, fan module, and electrical connections | Replace faulty components |
E11 | Heating Fault (NTC) | Incorrect NTC resistance value or wiring issue | Measure NTC resistance, inspect cables and connectors | Replace NTC resistor if needed |
E12 | Heating Fault (NTC) | NTC resistance value out of range (no drying) | Measure NTC resistance | Replace faulty NTC sensor |
E13 | Overheating | Water temperature above 75°C | Check water inlet temperature | No repair needed if inlet temp is normal |
E14 | Water Filling | Program interrupted due to missing flow meter pulses | Inspect flow meter (reed switch) and connections | Replace flow meter if needed |
E15 | Water Tray Safety | Bottom tray safety switch triggered (water detected) | Investigate cause of water in the tray | Fix leak or water accumulation |
E16 | Inlet Valve | Water detected without inlet valve being powered | Check fill valve and electrical supply | Replace or repair fill valve |
E17 | Water Inlet | Excessive water inflow detected | Check fill valve and flow regulator | Adjust or replace flow regulator |
E18 | Water Inlet | No or insufficient water detected | Inspect pressure chamber, pressure switch, and solenoid valve | Clean pressure chamber |
E20 | Circulation Pump | Circulation pump resistance out of range | Check cables/connectors, measure winding resistance | Replace circulation pump |
E21 | Circulation Pump | Circulation pump blocked | Inspect for foreign objects | Remove blockage or replace pump |
E22 | Drain Pump | Residual water due to clogged filters | Clean filters | Clean filters |
E23 | Drain Pump | Faulty drain pump (resistance values incorrect) | Check wiring/connectors and pump resistance | Replace drain pump |
E24, E25 | Drain Pump | Draining issue or leak in check valve | Check for: check valve leak, missing pump cover, blocked pipe, incorrect drain height | Fix installation issues or replace pump |